員工更衣、貯物櫃、休息空間要求?(QLD)
staff-amenities-change · 州別版02數字表
| 要求 | 數值 | 條文 | 適用情況 |
|---|---|---|---|
| 對向兩排儲物櫃之間最小通道 | 1800 mm | section 3 facilities — change rooms & lockers(pp.20–21) +10 條 | 全部情況 |
| 儲物櫃與座位或牆之間最小距離 | 900 mm | section 3 facilities — lockers spacing | 全部情況 |
| 更衣室人均淨空間(全國 WHS CoP §3.7/VIC ¶99) | 0.5 m²/人 | section 3 facilities — locker aisle distances | workers change clothing at work |
| 淋浴格密度(全國 WHS CoP §3.8) | 10 人/格 | 3. Facilities §3.7 Change rooms | workers need to shower — 1 cubicle per 10 workers |
| 用飯區人均淨空間(全國 WHS CoP §3.5) | 1 m²/人 | 3. Facilities §3.8 Shower facilities | dedicated eating area |
03Inspector 實睇乜
- 更衣空間有冇凳/鏡/掛鈎或層架
- 儲物櫃通風、有鎖、夠放衣物私人物品
- 對向儲物櫃之間 1800mm 通道有冇被雜物佔用
- 員工設施有冇同顧客區/工作區合理分隔
04做錯幾多錢 + 幾時要決定
做錯成本:後加員工設施通常要侵蝕儲存或工作面積,甚至改間隔牆;圖則階段預留係最平。WHS 唔合規可被要求整改。
幾時要決定:圖則階段預留面積;租約前都應確認有冇空間。
最常撞板:
- 圖則冇預留員工更衣/儲物空間,開業先嚟搵位
- 儲物櫃塞入去水喉或貨物通道旁邊
- 更衣同洗手設施完全無分隔
05州別差異
| 州 | 數值 | 備註 |
|---|---|---|
| QLD | — | 全國基準(NCC 2022)適用;本主題未見該州已核實額外要求 — 州級批核/牌照制度另見該州專頁。 |
06常見問題
WHS Regulation 第 40 條要求 PCBU 為員工提供設施,守則列出更衣室與儲物櫃具體標準:更衣室要方便到達、有座位/鏡/掛鈎層架;
有提供更衣室嘅話,合理可行範圍內應提供儲物櫃,並訂明通風穩陣夠大,同埋對向儲物櫃列間 1800mm、櫃與座位或牆 900mm 嘅通道尺寸。
食物處所方面員工個人物品貯存另受 FSANZ 3.2.3 clause 15(Storage facilities)規管。
員工設施唔可以因為營運方便而剝削(NCC 指明某些場所嘅設施豁免唔適用於員工設施)。
員工更衣、貯物櫃、休息空間要求?
員工需要換衫嘅工作要提供更衣室,入面要有凳畀同時更衣嘅人坐、有鏡、有足夠掛鈎或層架。儲物櫃要通風、穩陣、夠大;兩排對面儲物櫃之間最少留 1800mm,
儲物櫃同座位或牆之間最少 900mm(來源:Safe Work Australia《Managing the work environment and facilities》CoP §3 更衣室指引)。
呢條係法定要求定係行業做法?
有官方文件、條款號、快照同 sha256,數值喺原文 grep 得到。
做錯會點?要幾時決定?
後加員工設施通常要侵蝕儲存或工作面積,甚至改間隔牆;圖則階段預留係最平。WHS 唔合規可被要求整改。 時間點:圖則階段預留面積;租約前都應確認有冇空間。
07來源同核實日期
| 機構/文件 | 條款 | 核實日/sha256 | 連結 |
|---|---|---|---|
| Safe Work Australia Managing the work environment and facilities — Code of Practice (May 2018) | section 3 facilities — change rooms & lockers(pp.20–21) | 2026-10-28 2abb1f314003b3e2… | 原文 |
| Safe Work Australia Managing the work environment and facilities — Code of Practice (May 2018) | section 3 facilities — lockers spacing | 2026-10-28 2abb1f314003b3e2… | 原文 |
| Safe Work Australia Managing the work environment and facilities — Code of Practice (May 2018) | section 3 facilities — locker aisle distances | 2026-10-28 2abb1f314003b3e2… | 原文 |
| Safe Work Australia (Cth) Model Code of Practice: Managing the work environment and facilities (2018) | 3. Facilities §3.7 Change rooms | 2026-10-28T10:06:15 2abb1f314003b3e2… | 原文 |
| Safe Work Australia (Cth) Model Code of Practice: Managing the work environment and facilities (2018) | 3. Facilities §3.8 Shower facilities | 2026-10-28T10:06:15 2abb1f314003b3e2… | 原文 |
| Safe Work Australia (Cth) Model Code of Practice: Managing the work environment and facilities (2018) | 3. Facilities §3.5 Eating facilities | 2026-10-28T10:06:15 2abb1f314003b3e2… | 原文 |
| WorkSafe Victoria Compliance code: Workplace facilities and the working environment (Edition 1, December 2023) | Part 2 – Facilities ¶90(Personal storage) | 2026-10-28T10:06:15 1614a80049e9bc23… | 原文 |
| WorkSafe Victoria Compliance code: Workplace facilities and the working environment (Edition 1, December 2023) | Part 2 – Facilities ¶99(Changing rooms) | 2026-10-28T10:06:15 1614a80049e9bc23… | 原文 |
| WorkSafe Victoria Compliance code: Workplace facilities and the working environment (Edition 1, December 2023) | Part 2 – Facilities ¶103(Storage lockers) | 2026-10-28T10:06:15 1614a80049e9bc23… | 原文 |
| WorkSafe Victoria Compliance code: Workplace facilities and the working environment (Edition 1, December 2023) | Part 2 – Facilities ¶103(locker dimensions) | 2026-10-28T10:06:15 1614a80049e9bc23… | 原文 |
| WorkSafe Victoria Compliance code: Workplace facilities and the working environment (Edition 1, December 2023) | Part 2 – Facilities ¶104(locker clear space) | 2026-10-28T10:06:15 1614a80049e9bc23… | 原文 |
每條都存有本地快照,sha256 可對檔;數值必須喺快照原文出現過。
來源所屬州:以下官方來源屬 VIC,係呢個主題唯一已核實嘅一手來源。QLD 同其他州未有獨立核實來源,所以呢啲條文、數值同機構名唔會當成 QLD 要求;QLD 請以該州主管機構公布為準。
最後核實:2026-10-28T10:06:15 · 180 日後自動重驗